DAB-801

Q-SYS™ Amplifier and I/O Frame Backup Accessory


Features

  • One DAB-801 unit can provide N+1 instantaneous two-channel switchover redundancy for as many as eight amplifier output channels
  • Two DAB-801 units can be cascaded to provide two- or four-channel switchover redundancy for up to 16 amplifier output channels
  • Automatic detection and switchover between inputs from primary and backup I/O Frames, in case of failure upstream
  • Fault tolerant control and monitoring of each DAB-801 is available using simultaneous GPIO terminals connected to both primary and backup I/O Frames
  • Two additional non-networked analog “high line” level inputs provide emergency evacuation signal which can override all other input signals
  • QSC DataPort connectors and high-current terminal blocks for easy and reliable installation
  • Q-SYS technical support is available 24/7 worldwide
SPECIFICATIONS DAB-801
Connectors
   Input
   Output
   Other
6 position “Euro” or “Phoenix” type, QSC DataPort (HD-15), QSC GPIO (DB-15).
QSC DataPort (HD-15), 8 position high current “Euro” or “Phoenix” type.
Control Extension Bus (DB-37), IEC type AC Inlet.
Controls Page assignment: 8-position DIP type toggle switch
Page/Alarm Inputs Balanced 5 kO, 3 V rms
LED Indicators Power (blue, 1 each).
NORMAL (green, 8 each, 1 per primary DP).
FAULT (red, 8 each, 1 per primary DP).
BACKUP ACTIVE (yellow, 6 each, 1 per backup DP)
Maximum Amplifier
Ratings
1200 W per channel
Power Requirements 100–240 VAC, 50–60 Hz, 12 W max.
Operating Temperature
(Tma)
0–40°C non condensing
Dimensions (HWD) inches 7 × 19 × 2 / 4RU
Dimensions (HWD) mm 178 x 483 x 51 / 4RU
Weight (net) 7.8 lb / 3.5 kg
Weight (shipping) 10.8 lb / 5 kg